Testing of 48V Battery Management System
For a battery manufacturer in Germany we delivered the testing application for the new 48 Volt battery management system. The new 48 Volt battery for hybrids is helping a great deal on saving fuel and thereby producing remarkably less CO2 emissions.
Testing System
15 x DAQ systems with a total of 40-60 input channels for measuring voltage and temperature on the cells with interface to the client's DAQ software using Modbus, Ethernet, EtherCAT.
Specials
-
Sample rate per channel up to 100 kHz
-
Galvanic isolation channel 100/500/1200 VDC
-
High precision of temperature measurement using TC , Pt100/Pt1000, NTC
Download the case study to find out more about how the 48-Volt battery was tested and which Gantner Instruments products were used.