High accuracy in high voltage battery management testing

In this application for our German client ACCUmotive, a subsidiary of Daimler AG, we tested high density battery packs. The testing of this high voltage battery management system focused on the simulation of temperature profiles and thermo-mechanical load conditions. The testing was set up to prove the suitability of all new materials and components.

 

Testing System

Measured parameters were voltage, current, and temperature cycles, with a logging speed from 1Hz to 1kHz - all on a potential of +/-500V which required permanent channel to channel isolation.

The testing set up consisted of 15 DAQ systems with different measurement modules for voltage, resistance, temperature and more.

 

Specials

  • One Q.station collect data from four battery pacs
  • Q.bloxx A128 with +- 500 V range

 

Download the case study to find out more about how voltage, current, and temperature cycles were measured to prove the suitability of all new materials and components.